High-performance vertical IPL/DPL workstation integrating 7 interchangeable optical filters, bipolar RF energy, and double semiconductor sapphire cooling for rapid permanent hair reduction, vascular therapy, and comprehensive photorejuvenation across all skin tones.
Product Overview
Key Features
7 Precision Optical Filters
15×50mm Sapphire Crystal Spot
Integrated Bipolar RF Synergy
Double Semiconductor Cooling
UK Xenon Lamp 500,000+ Shots
Applications
Hair Removal (I-VI)
Vascular & Redness
Pigment Clearance
Acne & Rejuvenation
Technical parameter
| Feature | Photorejuvenation & Hair Removal | Technology | IPL + DPL + Bipolar RF |
| Warranty | 2 Years | After-Sales Service | Online Support |
| Model Number | YA-S IPL Series | Place of Origin | Shandong, China |
| Brand Name | HUAMEI | Product Name | Vertical IPL Machine |
| Screen | Intelligent LCD Touch Screen | OEM & ODM | Available |
| Spot Size | 15 × 50 mm Sapphire Spot | Lamp Lifespan | 500,000+ Shots UK Lamp |
| Filter Wavelengths | 420 / 530 / 560 / 590 / 640 / 690 / 750nm | Cooling System | Air + Water + TEC Cooling |
| Energy Density | 1 – 50 J/cm² Adjustable |
Packaging and Delivery
| Selling Units | Single Item | Single Package Size | 65 × 60 × 125 cm |
| Single Gross Weight | 70.0 kg | Lead Time | 1–10 Sets: 7 Days |
Product Introduction

The YA-S Vertical IPL & DPL Aesthetic System is a medical-grade multi-application optical workstation engineered for high-volume dermatology centers, aesthetic clinics, and medspas. Featuring high-energy broad-spectrum pulsed light combined with synergistic bipolar radiofrequency (RF) and 7 interchangeable magnetic cutoff filters (420nm to 750nm), the device provides comprehensive treatments for permanent hair reduction, facial telangiectasia, epidermal pigmented lesions, active inflammatory acne, and photoaging. Built with an expansive 15×50mm sapphire contact crystal, long-life UK-imported xenon flash lamps (500,000+ pulses), and double TEC semiconductor contact cooling, the YA-S ensures optimal maximum treatment comfort, rapid clinical throughput, and outstanding practice profitability.

Technology Principle
Operating on Selective Photothermolysis and Electro-Optical Synergy, the system emits targeted broad-spectrum light pulses absorbed by specific chromophores—melanin in hair follicles and pigmented spots, oxyhemoglobin in vascular telangiectasias, and porphyrins in acne bacteria. The converted thermal energy causes selective photocoagulation of target structures without damaging the surrounding epidermal layer. Concurrently, bipolar RF delivers controlled electrical currents into the deep reticular dermis, heating water molecules to stimulate fibroblast contraction and neocollagenesis. Integrated double semiconductor cooling maintains continuous sapphire surface contact at an ice-cool temperature, eliminating thermal discomfort and preventing surface burns across Fitzpatrick skin types I through VI.

Technical Advantage
- 420nm & 530nm Filters (Acne Sterilization & Epidermal Pigment): The 420nm wavelength activates endogenous porphyrins to destroy P. acnes bacteria, while 530nm selectively shatters superficial freckles, lentigines, and sun-damaged epidermal spots.
- 560nm & 590nm Filters (Photorejuvenation & Vascular Clearance): 560nm stimulates collagen synthesis for overall skin tightening and pore reduction, while 590nm targets oxyhemoglobin to collapse facial spider veins, diffuse redness, and rosacea.
- 640nm, 690nm & 750nm Filters (Full-Spectrum Hair Removal): Provides tiered optical penetration for light-colored, brown, and dark coarse hairs, delivering rapid and permanent hair reduction across large body areas via the 15×50mm spot.
- Integrated Bipolar RF & Double Semiconductor Cooling: Enhances deep dermal tissue tightening and wrinkle reduction through non-optical RF thermal pathways while dual TEC cooling pads ensure safe, high-comfort treatments.
Advantages
7 magnetic cutoff filters (420–750nm) covering complete aesthetic indications
Large 15×50mm sapphire crystal spot cutting full-body session times by 50%
UK-imported xenon flash lamp delivering over 500,000+ stable pulses
Bipolar RF technology synergistically enhancing collagen remodeling
Double TEC semiconductor contact cooling allowing 12 hours continuous work
Intuitive color touchscreen with smart clinical presets for all skin phototypes
Treatment Effects
80%–90% permanent hair reduction achieved across all body zones
Visible clearance of facial telangiectasia, spider veins, and rosacea redness
Significant fading of freckles, sun-induced age spots, and epidermal macules
Noticeable improvement in active acne, skin tone radiance, and pore refinement
FAQ
The 7 optical filters isolate specific light spectra ranging from 420nm to 750nm. This allows practitioners to precisely target different chromophores—using shorter wavelengths (420–530nm) for acne and freckles, medium wavelengths (560–590nm) for collagen and vascular lesions, and longer wavelengths (640–750nm) for diverse hair types.
Bipolar RF delivers electrical energy that penetrates into the deep dermis independently of skin melanin levels. Combined with IPL light energy, it allows lower optical fluences to be used safely on all skin tones while delivering superior collagen remodeling and skin tightening.
Dual TEC semiconductor cooling pads maintain the 15×50mm sapphire crystal continuously cold during pulsing. This chills the epidermis before, during, and after light discharge, preventing thermal pain and superficial burns while enabling 12 hours of uninterrupted clinic operation.
Permanent hair reduction typically requires 4 to 6 sessions spaced 4 to 6 weeks apart. Photorejuvenation, vascular redness, and epidermal pigment clearance usually achieve noticeable improvement in 3 to 5 sessions.
No. IPL/DPL treatments are completely non-invasive with minimal downtime. Patients may experience mild transient erythema that resolves within a few hours, allowing immediate return to work, makeup application, and daily activities.